Design Example - Building Construction

Loads
live loads
Building Classification Minimum Uniformly 
Distributed Load (psf)
Libraries  
     reading rooms 60
  book stacks 150
Offices  
  office spaces 80
  lobbies 100
Residential  
  private dwellings 40
  apartment units, hotel rooms 40
  public rooms 100
  corridors 60
Schools  
  classrooms 40
  corridors 100
Sidewalks and Vehicular Drives 250
Stairs, Fire Escapes, Exitways 100

lumber
Nominal Size Actual Size
2 X 4
1 1/2"  X  3 1/2"
2 X 6
1 1/2"  X  5 1/2"
2 X 8
1 1/2"  X  7 1/4"
2 X 10
1 1/2"  X  9 1/4"
2 X 12
  1 1/2"  X  11 1/4"

deflection limits
Structural Component Live Load
Only
Live Load
+ Dead Load
Roof Beams    
     industrial L/180 L/120
  commercial and institutional    
       without plaster ceiling L/240 L/180
    with plaster ceiling L/360 L/240
Floor Beams L/360 L/240
Highway Bridge Stringers L/300  
Railway Bridge Stringers L/300 to L/400  

Etc.

Plans and Models

 
 

Construction Steps

clearing, foundation, utilities

 framing, sheathing, roofing
wiring, insulation, ductwork

drywall, paint, flooring, trim, fixtures

landscape, paving

steel + wood