Estimated Specimen Usage Per Semester
for 10 lab sections with 21 students divided
into 7 groups of 3 students each
Experiment
Specimens Needed
(this includes enough for the TAs to practice with)Tension Test
- (75) 0.25"-diameter x 10"-long A36-steel specimens
- (50) 0.25"-diameter x 10"-long 2024-aluminum specimens
- (75) 0.625"-diameter x 12"-long A36-steel specimens
- (50) 0.625"-diameter x 12"-long 2024-aluminum specimens
- (50) 0.25"-thick x 1"-wide x 12"-long 2024-aluminum specimens
- an assort of other items
Torsion Testing &
Fully-Plastic Action
- (70) 0.625"-diameter x 22"-long specimens
Fastener Testing
- (100) 3/8"-diameter x 2.5"-long bolts (grade-2, 16-thread-per-inch, boxes of 50 available at Lowes)
- misc. nuts, bolts, washers
Strain Transformation
- 120 specimens (40 sheets of overhead projector transparencies)
~200' of 5/8" A36 per semester, ordered 800' on 6/7/2011 for $640, Bill's Welding (Kathy) 364-5738
Experiment
Total Specimen Usage Tension Test (100) 12" specimens
φ0.24" to 0.7" cylindrical
0" to 0.79" x 0" to 3" rectangular(100) 10" specimens
φ0.24" to 0.7" cylindrical
0" to 0.25" x 0" to 1" rectangularHardness Testing (150) φ5/8"x1.5" specimens
(can be used for 3 semesters)Torsion Testing &
Fully-Plastic Action(70) φ5/8"x22" specimens Wood Connections (4) 1"x2"x48" pine
(3) 1"x3"x72" pine
(25) MP14 mending plates
(30) MP24 mending plates
2x4s for dowel bearing testsFastener Testing (100) 3/8"x2.5" bolts (boxes of 50)
misc. nuts, bolts, washersStrain Transformation 40 sheets of overhead projector transparencies
(120 specimens)Compression Testing 2x4s