Problem 2.3

 

 

Dead Loads

 

roof + ceiling

 

Component D (psf) Reference
5 ply roof with gravel (felt) 6.5 Appendix B.2
1/2" plywood 3.0/in. Appendix B.1
roof truss @ 24" O.C. 9 lb/ft given
suspended acoustic ceiling system
  - acoustical fiber tile
  - channel-suspended system

1.0
1.0
Appendix B.3

 

D = 6.5 + 1/2 * 3.0 + 9 / 2A  + 1.0 + 1.0 = 14.5 psf

A The 9 /b/ft is spread across a 24" distance into the page, and we need the weight per 12" into the page.

 

second floor + ceiling

 

Component D (psf) Reference
movable partitionB 15 ASCE 7 sec. 4.2.2, IBC sec. 1607.5
1-1/2" concrete 150C  given
5/8" T&G plywood 3.0/in. Appendix B.1
2x10 @ 16" O.C. 2.4 Appendix A.1
air duct 0.5 given
suspended ceiling
  - acoustical fiber tile
  - channel-suspended system

1.0
1.0
Appendix B.3

 

D = 1.5 * 150 / 12C + 5/8 * 3.0 + 2.4 + 0.5 + 1.0 + 1.0 = 25.53 psf

B The partition would be a live load instead of dead.

C The book says 150 psf, but it must be 150 lb/ft3 or 15.0 psf.  As a comparison, stone concrete is 12.5 psf according to Appendix B.3.

 

Live Loads

 

roof

 

Term Value Reference
L0 20 psf (at 0:12) ASCE 7 table 4-1
R1 1 (assume AT ≤ 200 ft2) ASCE 7 section 4.9.1
R2 1 (F ≤ 4) ASCE 7 section 4.9.1

 

Lr = 1 * 1 * 20 psf = 20 psf