CE 322 - Wood Structures
taught by J. Thomas in the department of
Civil, Architectural and Environmental Engineering
at Missouri University of Science and Technology

Problem 8.20

 

Given

 

Application joists in flat roof
Spacing 24 in. OC
Load D = 8 psf
S = 100 psf
Type of panel APA rated sheathing (plywood or nonveneer panel)
Orientation strong direction

 

 

Deflection Limits  (IBC table 1604.3)

 

Roof members L
(100 psf)
S or W
(100 psf)
D + L
(108 psf)
supporting plaster ceiling L/360 L/360 L/240
supporting non-plaster ceiling L/240 L/240 L/180
not supporting ceiling L/180 L/180 L/120

 

 

Span Rating  (Load-Span Tables for APA Structural-Use Panels)

 

Try a 40/20 with joists supporting a plaster ceiling.

L L/360 108 psf > 100 psf  ✓
S or W L/360 108 psf > 100 psf  ✓
D + L L/240 163 psf > 108 psf  ✓
Bending 1.15(130 psf) = 149.5 psf > 108 psf  ✓
Shear 1.15(218 psf) = 250.7 psf > 108 psf  ✓

 Try a 40/20 with joists supporting a non-plaster ceiling.

L L/240 163 psf > 100 psf  ✓
S or W L/240 163 psf > 100 psf  ✓
D + L L/180 217 psf > 108 psf  ✓
Bending 1.15(130 psf) = 149.5 psf > 108 psf  ✓
Shear 1.15(218 psf) = 250.7 psf > 108 psf  ✓

 Try a 40/20 with joists not supporting a ceiling.

L L/180 217 psf > 100 psf  ✓
S or W L/180 217 psf > 100 psf  ✓
D + L L/120 ?? psf > 108 psf  - probably okay since above (more-conservative) ceiling options were okay
Bending 1.15(130 psf) = 149.5 psf > 108 psf  ✓
Shear 1.15(218 psf) = 250.7 psf > 108 psf  ✓

 ∴ A 40/20 span rating or larger would work for APA rated plywood sheathing.

 

Try a 48/24 with joists supporting a plaster ceiling.

L L/360 174 psf > 100 psf  ✓
S or W L/360 174 psf > 100 psf  ✓
D + L L/240 260 psf > 108 psf  ✓
Bending 1.15(208 psf) = 239.2 psf > 108 psf  ✓
Shear 1.15(222 psf) = 255.3 psf > 108 psf  ✓

 Try a 48/24 with joists supporting a non-plaster ceiling.

L L/240 260 psf > 100 psf  ✓
S or W L/240 260 psf > 100 psf  ✓
D + L L/180 347 psf > 108 psf  ✓
Bending 1.15(208 psf) = 239.2 psf > 108 psf  ✓
Shear 1.15(222 psf) = 255.3 psf > 108 psf  ✓

 Try a 48/24 with joists not supporting a ceiling.

L L/180 347 psf > 100 psf  ✓
S or W L/180 347 psf > 100 psf  ✓
D + L L/120 ?? psf > 108 psf  - probably okay since above (more-conservative) ceiling options were okay
Bending 1.15(208 psf) = 239.2 psf > 108 psf  ✓
Shear 1.15(222 psf) = 255.3 psf > 108 psf  ✓

 ∴ A 48/24 span rating or larger would work for APA rated OSB sheathing.

 

 

Thickness  (Panel Design Specification)

 

 ∴ A 19/32 in. thickness or larger would work for APA rated plywood sheathing.  A 23/32 in. thickness or larger would work for APA rated OSB sheathing.

 

 

Edge Support  (ASD-LRFD Manual)

 

∴ Edge support is not required for a 24 in. span.

 

 

Conclusion

 

Minimum grade APA rated
plywood sheathing
APA rated
OSB sheathing
Span rating 40/20 48/24
Thickness 19/32 in. or greater 23/32 in. or greater
Edge support not required not required