Problem 8.20

 

Given

 

Application joists in flat roof
Spacing 24 in. OC
Load D = 8 psf
S = 100 psf
Type of panel APA rated sheathing (plywood or nonveneer panel)
Orientation strong direction

 

 

Deflection Limits  (IBC table 1604.3)

 

Roof members L
(100 psf)
S or W
(100 psf)
D + L
(108 psf)
supporting plaster ceiling L/360 L/360 L/240
supporting non-plaster ceiling L/240 L/240 L/180
not supporting ceiling L/180 L/180 L/120

 

 

Span Rating  (Load-Span Tables for APA Structural-Use Panels)

 

Try a 40/20 with joists supporting a plaster ceiling.

L L/360 108 psf > 100 psf  ✓
S or W L/360 108 psf > 100 psf  ✓
D + L L/240 163 psf > 108 psf  ✓
Bending 1.15(130 psf) = 149.5 psf > 108 psf  ✓
Shear 1.15(218 psf) = 250.7 psf > 108 psf  ✓

 Try a 40/20 with joists supporting a non-plaster ceiling.

L L/240 163 psf > 100 psf  ✓
S or W L/240 163 psf > 100 psf  ✓
D + L L/180 217 psf > 108 psf  ✓
Bending 1.15(130 psf) = 149.5 psf > 108 psf  ✓
Shear 1.15(218 psf) = 250.7 psf > 108 psf  ✓

 Try a 40/20 with joists not supporting a ceiling.

L L/180 217 psf > 100 psf  ✓
S or W L/180 217 psf > 100 psf  ✓
D + L L/120 ?? psf > 108 psf  - probably okay since above (more-conservative) ceiling options were okay
Bending 1.15(130 psf) = 149.5 psf > 108 psf  ✓
Shear 1.15(218 psf) = 250.7 psf > 108 psf  ✓

 ∴ A 40/20 span rating or larger would work for APA rated plywood sheathing.

 

Try a 48/24 with joists supporting a plaster ceiling.

L L/360 174 psf > 100 psf  ✓
S or W L/360 174 psf > 100 psf  ✓
D + L L/240 260 psf > 108 psf  ✓
Bending 1.15(208 psf) = 239.2 psf > 108 psf  ✓
Shear 1.15(222 psf) = 255.3 psf > 108 psf  ✓

 Try a 48/24 with joists supporting a non-plaster ceiling.

L L/240 260 psf > 100 psf  ✓
S or W L/240 260 psf > 100 psf  ✓
D + L L/180 347 psf > 108 psf  ✓
Bending 1.15(208 psf) = 239.2 psf > 108 psf  ✓
Shear 1.15(222 psf) = 255.3 psf > 108 psf  ✓

 Try a 48/24 with joists not supporting a ceiling.

L L/180 347 psf > 100 psf  ✓
S or W L/180 347 psf > 100 psf  ✓
D + L L/120 ?? psf > 108 psf  - probably okay since above (more-conservative) ceiling options were okay
Bending 1.15(208 psf) = 239.2 psf > 108 psf  ✓
Shear 1.15(222 psf) = 255.3 psf > 108 psf  ✓

 ∴ A 48/24 span rating or larger would work for APA rated OSB sheathing.

 

 

Thickness  (Panel Design Specification)

 

 ∴ A 19/32 in. thickness or larger would work for APA rated plywood sheathing.  A 23/32 in. thickness or larger would work for APA rated OSB sheathing.

 

 

Edge Support  (ASD-LRFD Manual)

 

∴ Edge support is not required for a 24 in. span.

 

 

Conclusion

 

Minimum grade APA rated
plywood sheathing
APA rated
OSB sheathing
Span rating 40/20 48/24
Thickness 19/32 in. or greater 23/32 in. or greater
Edge support not required not required