Sample House
ROOF LEVEL
Ceiling
- dimensions
- sqft
- dead load
- pressure
- insulation: 14" fiberglass = 0.5 x 14 = 7 psf
- ceiling joist: 2x8 at 16" OC = 1.6123 psf
- drywall: 5/8" gypsum board = 5 x 5/8 = 3.125 psf
- D = 11.8 psf
- load to joist
- AT = 16 in. (1 ft/12 in.) x (14 ft) = 18.67 ft2
- wD = 11.8 psf x 16 in. (1 ft/12 in.) = 15.73 lb/ft
- load to stud in interior wall
- AT = 16 in. (1 ft/12 in.) x (7 ft) x 2 sides = 18.67 ft2
- PD = D AT = 220.3 lb
- load to stud in exterior side wall
- AT = 16 in. (1 ft/12 in.) x (7 ft) = 9.333 ft2
- PD = D AT = 110.1 lb
- live load
- pressure
- L0 = 10 psf (uninhabitable attics without storage, ASCE 7 table 4-1)
- load to joist
- AT = 16 in. (1 ft/12 in.) x (14 ft) = 18.67 ft2
- wL = 10 psf x 16 in. (1 ft/12 in.) = 13.33 lb/ft
- load to stud in interior wall
- AT = 16 in. (1 ft/12 in.) x (7 ft) x 2 sides = 18.67 ft2
- PL = L AT = 186.7 lb
- load to stud in exterior side wall
- AT = 16 in. (1 ft/12 in.) x (7 ft) = 11.00 ft2
- PL = L AT = 110.0 lb
- snow load
- wind load
- seismic load
- deflection limits (IBC table 1604.3)
- supporting nonplaster ceiling
- L/240 for L = 14 ft x 12in./ft / 240 = 0.7000 in.
- L/240 for S or W = 14 ft x 12in./ft / 240 = 0.7000 in.
- L/180 for D + L (or L + 0.5D if under dry conditions) = 14 ft x 12in./ft / 180 = 0.9333 in.